]> Cypherpunks.ru repositories - gostls13.git/blob - doc/asm.html
cmd/compile/internal/inline: score call sites exposed by inlines
[gostls13.git] / doc / asm.html
1 <!--{
2         "Title": "A Quick Guide to Go's Assembler",
3         "Path":  "/doc/asm"
4 }-->
5
6 <h2 id="introduction">A Quick Guide to Go's Assembler</h2>
7
8 <p>
9 This document is a quick outline of the unusual form of assembly language used by the <code>gc</code> Go compiler.
10 The document is not comprehensive.
11 </p>
12
13 <p>
14 The assembler is based on the input style of the Plan 9 assemblers, which is documented in detail
15 <a href="https://9p.io/sys/doc/asm.html">elsewhere</a>.
16 If you plan to write assembly language, you should read that document although much of it is Plan 9-specific.
17 The current document provides a summary of the syntax and the differences with
18 what is explained in that document, and
19 describes the peculiarities that apply when writing assembly code to interact with Go.
20 </p>
21
22 <p>
23 The most important thing to know about Go's assembler is that it is not a direct representation of the underlying machine.
24 Some of the details map precisely to the machine, but some do not.
25 This is because the compiler suite (see
26 <a href="https://9p.io/sys/doc/compiler.html">this description</a>)
27 needs no assembler pass in the usual pipeline.
28 Instead, the compiler operates on a kind of semi-abstract instruction set,
29 and instruction selection occurs partly after code generation.
30 The assembler works on the semi-abstract form, so
31 when you see an instruction like <code>MOV</code>
32 what the toolchain actually generates for that operation might
33 not be a move instruction at all, perhaps a clear or load.
34 Or it might correspond exactly to the machine instruction with that name.
35 In general, machine-specific operations tend to appear as themselves, while more general concepts like
36 memory move and subroutine call and return are more abstract.
37 The details vary with architecture, and we apologize for the imprecision; the situation is not well-defined.
38 </p>
39
40 <p>
41 The assembler program is a way to parse a description of that
42 semi-abstract instruction set and turn it into instructions to be
43 input to the linker.
44 If you want to see what the instructions look like in assembly for a given architecture, say amd64, there
45 are many examples in the sources of the standard library, in packages such as
46 <a href="/pkg/runtime/"><code>runtime</code></a> and
47 <a href="/pkg/math/big/"><code>math/big</code></a>.
48 You can also examine what the compiler emits as assembly code
49 (the actual output may differ from what you see here):
50 </p>
51
52 <pre>
53 $ cat x.go
54 package main
55
56 func main() {
57         println(3)
58 }
59 $ GOOS=linux GOARCH=amd64 go tool compile -S x.go        # or: go build -gcflags -S x.go
60 "".main STEXT size=74 args=0x0 locals=0x10
61         0x0000 00000 (x.go:3)   TEXT    "".main(SB), $16-0
62         0x0000 00000 (x.go:3)   MOVQ    (TLS), CX
63         0x0009 00009 (x.go:3)   CMPQ    SP, 16(CX)
64         0x000d 00013 (x.go:3)   JLS     67
65         0x000f 00015 (x.go:3)   SUBQ    $16, SP
66         0x0013 00019 (x.go:3)   MOVQ    BP, 8(SP)
67         0x0018 00024 (x.go:3)   LEAQ    8(SP), BP
68         0x001d 00029 (x.go:3)   FUNCDATA        $0, gclocals·33cdeccccebe80329f1fdbee7f5874cb(SB)
69         0x001d 00029 (x.go:3)   FUNCDATA        $1, gclocals·33cdeccccebe80329f1fdbee7f5874cb(SB)
70         0x001d 00029 (x.go:3)   FUNCDATA        $2, gclocals·33cdeccccebe80329f1fdbee7f5874cb(SB)
71         0x001d 00029 (x.go:4)   PCDATA  $0, $0
72         0x001d 00029 (x.go:4)   PCDATA  $1, $0
73         0x001d 00029 (x.go:4)   CALL    runtime.printlock(SB)
74         0x0022 00034 (x.go:4)   MOVQ    $3, (SP)
75         0x002a 00042 (x.go:4)   CALL    runtime.printint(SB)
76         0x002f 00047 (x.go:4)   CALL    runtime.printnl(SB)
77         0x0034 00052 (x.go:4)   CALL    runtime.printunlock(SB)
78         0x0039 00057 (x.go:5)   MOVQ    8(SP), BP
79         0x003e 00062 (x.go:5)   ADDQ    $16, SP
80         0x0042 00066 (x.go:5)   RET
81         0x0043 00067 (x.go:5)   NOP
82         0x0043 00067 (x.go:3)   PCDATA  $1, $-1
83         0x0043 00067 (x.go:3)   PCDATA  $0, $-1
84         0x0043 00067 (x.go:3)   CALL    runtime.morestack_noctxt(SB)
85         0x0048 00072 (x.go:3)   JMP     0
86 ...
87 </pre>
88
89 <p>
90 The <code>FUNCDATA</code> and <code>PCDATA</code> directives contain information
91 for use by the garbage collector; they are introduced by the compiler.
92 </p>
93
94 <p>
95 To see what gets put in the binary after linking, use <code>go tool objdump</code>:
96 </p>
97
98 <pre>
99 $ go build -o x.exe x.go
100 $ go tool objdump -s main.main x.exe
101 TEXT main.main(SB) /tmp/x.go
102   x.go:3                0x10501c0               65488b0c2530000000      MOVQ GS:0x30, CX
103   x.go:3                0x10501c9               483b6110                CMPQ 0x10(CX), SP
104   x.go:3                0x10501cd               7634                    JBE 0x1050203
105   x.go:3                0x10501cf               4883ec10                SUBQ $0x10, SP
106   x.go:3                0x10501d3               48896c2408              MOVQ BP, 0x8(SP)
107   x.go:3                0x10501d8               488d6c2408              LEAQ 0x8(SP), BP
108   x.go:4                0x10501dd               e86e45fdff              CALL runtime.printlock(SB)
109   x.go:4                0x10501e2               48c7042403000000        MOVQ $0x3, 0(SP)
110   x.go:4                0x10501ea               e8e14cfdff              CALL runtime.printint(SB)
111   x.go:4                0x10501ef               e8ec47fdff              CALL runtime.printnl(SB)
112   x.go:4                0x10501f4               e8d745fdff              CALL runtime.printunlock(SB)
113   x.go:5                0x10501f9               488b6c2408              MOVQ 0x8(SP), BP
114   x.go:5                0x10501fe               4883c410                ADDQ $0x10, SP
115   x.go:5                0x1050202               c3                      RET
116   x.go:3                0x1050203               e83882ffff              CALL runtime.morestack_noctxt(SB)
117   x.go:3                0x1050208               ebb6                    JMP main.main(SB)
118 </pre>
119
120 <h3 id="constants">Constants</h3>
121
122 <p>
123 Although the assembler takes its guidance from the Plan 9 assemblers,
124 it is a distinct program, so there are some differences.
125 One is in constant evaluation.
126 Constant expressions in the assembler are parsed using Go's operator
127 precedence, not the C-like precedence of the original.
128 Thus <code>3&amp;1&lt;&lt;2</code> is 4, not 0—it parses as <code>(3&amp;1)&lt;&lt;2</code>
129 not <code>3&amp;(1&lt;&lt;2)</code>.
130 Also, constants are always evaluated as 64-bit unsigned integers.
131 Thus <code>-2</code> is not the integer value minus two,
132 but the unsigned 64-bit integer with the same bit pattern.
133 The distinction rarely matters but
134 to avoid ambiguity, division or right shift where the right operand's
135 high bit is set is rejected.
136 </p>
137
138 <h3 id="symbols">Symbols</h3>
139
140 <p>
141 Some symbols, such as <code>R1</code> or <code>LR</code>,
142 are predefined and refer to registers.
143 The exact set depends on the architecture.
144 </p>
145
146 <p>
147 There are four predeclared symbols that refer to pseudo-registers.
148 These are not real registers, but rather virtual registers maintained by
149 the toolchain, such as a frame pointer.
150 The set of pseudo-registers is the same for all architectures:
151 </p>
152
153 <ul>
154
155 <li>
156 <code>FP</code>: Frame pointer: arguments and locals.
157 </li>
158
159 <li>
160 <code>PC</code>: Program counter:
161 jumps and branches.
162 </li>
163
164 <li>
165 <code>SB</code>: Static base pointer: global symbols.
166 </li>
167
168 <li>
169 <code>SP</code>: Stack pointer: the highest address within the local stack frame.
170 </li>
171
172 </ul>
173
174 <p>
175 All user-defined symbols are written as offsets to the pseudo-registers
176 <code>FP</code> (arguments and locals) and <code>SB</code> (globals).
177 </p>
178
179 <p>
180 The <code>SB</code> pseudo-register can be thought of as the origin of memory, so the symbol <code>foo(SB)</code>
181 is the name <code>foo</code> as an address in memory.
182 This form is used to name global functions and data.
183 Adding <code>&lt;&gt;</code> to the name, as in <span style="white-space: nowrap"><code>foo&lt;&gt;(SB)</code></span>, makes the name
184 visible only in the current source file, like a top-level <code>static</code> declaration in a C file.
185 Adding an offset to the name refers to that offset from the symbol's address, so
186 <code>foo+4(SB)</code> is four bytes past the start of <code>foo</code>.
187 </p>
188
189 <p>
190 The <code>FP</code> pseudo-register is a virtual frame pointer
191 used to refer to function arguments.
192 The compilers maintain a virtual frame pointer and refer to the arguments on the stack as offsets from that pseudo-register.
193 Thus <code>0(FP)</code> is the first argument to the function,
194 <code>8(FP)</code> is the second (on a 64-bit machine), and so on.
195 However, when referring to a function argument this way, it is necessary to place a name
196 at the beginning, as in <code>first_arg+0(FP)</code> and <code>second_arg+8(FP)</code>.
197 (The meaning of the offset—offset from the frame pointer—distinct
198 from its use with <code>SB</code>, where it is an offset from the symbol.)
199 The assembler enforces this convention, rejecting plain <code>0(FP)</code> and <code>8(FP)</code>.
200 The actual name is semantically irrelevant but should be used to document
201 the argument's name.
202 It is worth stressing that <code>FP</code> is always a
203 pseudo-register, not a hardware
204 register, even on architectures with a hardware frame pointer.
205 </p>
206
207 <p>
208 For assembly functions with Go prototypes, <code>go</code> <code>vet</code> will check that the argument names
209 and offsets match.
210 On 32-bit systems, the low and high 32 bits of a 64-bit value are distinguished by adding
211 a <code>_lo</code> or <code>_hi</code> suffix to the name, as in <code>arg_lo+0(FP)</code> or <code>arg_hi+4(FP)</code>.
212 If a Go prototype does not name its result, the expected assembly name is <code>ret</code>.
213 </p>
214
215 <p>
216 The <code>SP</code> pseudo-register is a virtual stack pointer
217 used to refer to frame-local variables and the arguments being
218 prepared for function calls.
219 It points to the highest address within the local stack frame, so references should use negative offsets
220 in the range [−framesize, 0):
221 <code>x-8(SP)</code>, <code>y-4(SP)</code>, and so on.
222 </p>
223
224 <p>
225 On architectures with a hardware register named <code>SP</code>,
226 the name prefix distinguishes
227 references to the virtual stack pointer from references to the architectural
228 <code>SP</code> register.
229 That is, <code>x-8(SP)</code> and <code>-8(SP)</code>
230 are different memory locations:
231 the first refers to the virtual stack pointer pseudo-register,
232 while the second refers to the
233 hardware's <code>SP</code> register.
234 </p>
235
236 <p>
237 On machines where <code>SP</code> and <code>PC</code> are
238 traditionally aliases for a physical, numbered register,
239 in the Go assembler the names <code>SP</code> and <code>PC</code>
240 are still treated specially;
241 for instance, references to <code>SP</code> require a symbol,
242 much like <code>FP</code>.
243 To access the actual hardware register use the true <code>R</code> name.
244 For example, on the ARM architecture the hardware
245 <code>SP</code> and <code>PC</code> are accessible as
246 <code>R13</code> and <code>R15</code>.
247 </p>
248
249 <p>
250 Branches and direct jumps are always written as offsets to the PC, or as
251 jumps to labels:
252 </p>
253
254 <pre>
255 label:
256         MOVW $0, R1
257         JMP label
258 </pre>
259
260 <p>
261 Each label is visible only within the function in which it is defined.
262 It is therefore permitted for multiple functions in a file to define
263 and use the same label names.
264 Direct jumps and call instructions can target text symbols,
265 such as <code>name(SB)</code>, but not offsets from symbols,
266 such as <code>name+4(SB)</code>.
267 </p>
268
269 <p>
270 Instructions, registers, and assembler directives are always in UPPER CASE to remind you
271 that assembly programming is a fraught endeavor.
272 (Exception: the <code>g</code> register renaming on ARM.)
273 </p>
274
275 <p>
276 In Go object files and binaries, the full name of a symbol is the
277 package path followed by a period and the symbol name:
278 <code>fmt.Printf</code> or <code>math/rand.Int</code>.
279 Because the assembler's parser treats period and slash as punctuation,
280 those strings cannot be used directly as identifier names.
281 Instead, the assembler allows the middle dot character U+00B7
282 and the division slash U+2215 in identifiers and rewrites them to
283 plain period and slash.
284 Within an assembler source file, the symbols above are written as
285 <code>fmt·Printf</code> and <code>math∕rand·Int</code>.
286 The assembly listings generated by the compilers when using the <code>-S</code> flag
287 show the period and slash directly instead of the Unicode replacements
288 required by the assemblers.
289 </p>
290
291 <p>
292 Most hand-written assembly files do not include the full package path
293 in symbol names, because the linker inserts the package path of the current
294 object file at the beginning of any name starting with a period:
295 in an assembly source file within the math/rand package implementation,
296 the package's Int function can be referred to as <code>·Int</code>.
297 This convention avoids the need to hard-code a package's import path in its
298 own source code, making it easier to move the code from one location to another.
299 </p>
300
301 <h3 id="directives">Directives</h3>
302
303 <p>
304 The assembler uses various directives to bind text and data to symbol names.
305 For example, here is a simple complete function definition. The <code>TEXT</code>
306 directive declares the symbol <code>runtime·profileloop</code> and the instructions
307 that follow form the body of the function.
308 The last instruction in a <code>TEXT</code> block must be some sort of jump, usually a <code>RET</code> (pseudo-)instruction.
309 (If it's not, the linker will append a jump-to-itself instruction; there is no fallthrough in <code>TEXTs</code>.)
310 After the symbol, the arguments are flags (see below)
311 and the frame size, a constant (but see below):
312 </p>
313
314 <pre>
315 TEXT runtime·profileloop(SB),NOSPLIT,$8
316         MOVQ    $runtime·profileloop1(SB), CX
317         MOVQ    CX, 0(SP)
318         CALL    runtime·externalthreadhandler(SB)
319         RET
320 </pre>
321
322 <p>
323 In the general case, the frame size is followed by an argument size, separated by a minus sign.
324 (It's not a subtraction, just idiosyncratic syntax.)
325 The frame size <code>$24-8</code> states that the function has a 24-byte frame
326 and is called with 8 bytes of argument, which live on the caller's frame.
327 If <code>NOSPLIT</code> is not specified for the <code>TEXT</code>,
328 the argument size must be provided.
329 For assembly functions with Go prototypes, <code>go</code> <code>vet</code> will check that the
330 argument size is correct.
331 </p>
332
333 <p>
334 Note that the symbol name uses a middle dot to separate the components and is specified as an offset from the
335 static base pseudo-register <code>SB</code>.
336 This function would be called from Go source for package <code>runtime</code> using the
337 simple name <code>profileloop</code>.
338 </p>
339
340 <p>
341 Global data symbols are defined by a sequence of initializing
342 <code>DATA</code> directives followed by a <code>GLOBL</code> directive.
343 Each <code>DATA</code> directive initializes a section of the
344 corresponding memory.
345 The memory not explicitly initialized is zeroed.
346 The general form of the <code>DATA</code> directive is
347
348 <pre>
349 DATA    symbol+offset(SB)/width, value
350 </pre>
351
352 <p>
353 which initializes the symbol memory at the given offset and width with the given value.
354 The <code>DATA</code> directives for a given symbol must be written with increasing offsets.
355 </p>
356
357 <p>
358 The <code>GLOBL</code> directive declares a symbol to be global.
359 The arguments are optional flags and the size of the data being declared as a global,
360 which will have initial value all zeros unless a <code>DATA</code> directive
361 has initialized it.
362 The <code>GLOBL</code> directive must follow any corresponding <code>DATA</code> directives.
363 </p>
364
365 <p>
366 For example,
367 </p>
368
369 <pre>
370 DATA divtab&lt;&gt;+0x00(SB)/4, $0xf4f8fcff
371 DATA divtab&lt;&gt;+0x04(SB)/4, $0xe6eaedf0
372 ...
373 DATA divtab&lt;&gt;+0x3c(SB)/4, $0x81828384
374 GLOBL divtab&lt;&gt;(SB), RODATA, $64
375
376 GLOBL runtime·tlsoffset(SB), NOPTR, $4
377 </pre>
378
379 <p>
380 declares and initializes <code>divtab&lt;&gt;</code>, a read-only 64-byte table of 4-byte integer values,
381 and declares <code>runtime·tlsoffset</code>, a 4-byte, implicitly zeroed variable that
382 contains no pointers.
383 </p>
384
385 <p>
386 There may be one or two arguments to the directives.
387 If there are two, the first is a bit mask of flags,
388 which can be written as numeric expressions, added or or-ed together,
389 or can be set symbolically for easier absorption by a human.
390 Their values, defined in the standard <code>#include</code>  file <code>textflag.h</code>, are:
391 </p>
392
393 <ul>
394 <li>
395 <code>NOPROF</code> = 1
396 <br>
397 (For <code>TEXT</code> items.)
398 Don't profile the marked function.  This flag is deprecated.
399 </li>
400 <li>
401 <code>DUPOK</code> = 2
402 <br>
403 It is legal to have multiple instances of this symbol in a single binary.
404 The linker will choose one of the duplicates to use.
405 </li>
406 <li>
407 <code>NOSPLIT</code> = 4
408 <br>
409 (For <code>TEXT</code> items.)
410 Don't insert the preamble to check if the stack must be split.
411 The frame for the routine, plus anything it calls, must fit in the
412 spare space remaining in the current stack segment.
413 Used to protect routines such as the stack splitting code itself.
414 </li>
415 <li>
416 <code>RODATA</code> = 8
417 <br>
418 (For <code>DATA</code> and <code>GLOBL</code> items.)
419 Put this data in a read-only section.
420 </li>
421 <li>
422 <code>NOPTR</code> = 16
423 <br>
424 (For <code>DATA</code> and <code>GLOBL</code> items.)
425 This data contains no pointers and therefore does not need to be
426 scanned by the garbage collector.
427 </li>
428 <li>
429 <code>WRAPPER</code> = 32
430 <br>
431 (For <code>TEXT</code> items.)
432 This is a wrapper function and should not count as disabling <code>recover</code>.
433 </li>
434 <li>
435 <code>NEEDCTXT</code> = 64
436 <br>
437 (For <code>TEXT</code> items.)
438 This function is a closure so it uses its incoming context register.
439 </li>
440 <li>
441 <code>LOCAL</code> = 128
442 <br>
443 This symbol is local to the dynamic shared object.
444 </li>
445 <li>
446 <code>TLSBSS</code> = 256
447 <br>
448 (For <code>DATA</code> and <code>GLOBL</code> items.)
449 Put this data in thread local storage.
450 </li>
451 <li>
452 <code>NOFRAME</code> = 512
453 <br>
454 (For <code>TEXT</code> items.)
455 Do not insert instructions to allocate a stack frame and save/restore the return
456 address, even if this is not a leaf function.
457 Only valid on functions that declare a frame size of 0.
458 </li>
459 <li>
460 <code>TOPFRAME</code> = 2048
461 <br>
462 (For <code>TEXT</code> items.)
463 Function is the outermost frame of the call stack. Traceback should stop at this function.
464 </li>
465 </ul>
466
467 <h3 id="data-offsets">Interacting with Go types and constants</h3>
468
469 <p>
470 If a package has any .s files, then <code>go build</code> will direct
471 the compiler to emit a special header called <code>go_asm.h</code>,
472 which the .s files can then <code>#include</code>.
473 The file contains symbolic <code>#define</code> constants for the
474 offsets of Go struct fields, the sizes of Go struct types, and most
475 Go <code>const</code> declarations defined in the current package.
476 Go assembly should avoid making assumptions about the layout of Go
477 types and instead use these constants.
478 This improves the readability of assembly code, and keeps it robust to
479 changes in data layout either in the Go type definitions or in the
480 layout rules used by the Go compiler.
481 </p>
482
483 <p>
484 Constants are of the form <code>const_<i>name</i></code>.
485 For example, given the Go declaration <code>const bufSize =
486 1024</code>, assembly code can refer to the value of this constant
487 as <code>const_bufSize</code>.
488 </p>
489
490 <p>
491 Field offsets are of the form <code><i>type</i>_<i>field</i></code>.
492 Struct sizes are of the form <code><i>type</i>__size</code>.
493 For example, consider the following Go definition:
494 </p>
495
496 <pre>
497 type reader struct {
498         buf [bufSize]byte
499         r   int
500 }
501 </pre>
502
503 <p>
504 Assembly can refer to the size of this struct
505 as <code>reader__size</code> and the offsets of the two fields
506 as <code>reader_buf</code> and <code>reader_r</code>.
507 Hence, if register <code>R1</code> contains a pointer to
508 a <code>reader</code>, assembly can reference the <code>r</code> field
509 as <code>reader_r(R1)</code>.
510 </p>
511
512 <p>
513 If any of these <code>#define</code> names are ambiguous (for example,
514 a struct with a <code>_size</code> field), <code>#include
515 "go_asm.h"</code> will fail with a "redefinition of macro" error.
516 </p>
517
518 <h3 id="runtime">Runtime Coordination</h3>
519
520 <p>
521 For garbage collection to run correctly, the runtime must know the
522 location of pointers in all global data and in most stack frames.
523 The Go compiler emits this information when compiling Go source files,
524 but assembly programs must define it explicitly.
525 </p>
526
527 <p>
528 A data symbol marked with the <code>NOPTR</code> flag (see above)
529 is treated as containing no pointers to runtime-allocated data.
530 A data symbol with the <code>RODATA</code> flag
531 is allocated in read-only memory and is therefore treated
532 as implicitly marked <code>NOPTR</code>.
533 A data symbol with a total size smaller than a pointer
534 is also treated as implicitly marked <code>NOPTR</code>.
535 It is not possible to define a symbol containing pointers in an assembly source file;
536 such a symbol must be defined in a Go source file instead.
537 Assembly source can still refer to the symbol by name
538 even without <code>DATA</code> and <code>GLOBL</code> directives.
539 A good general rule of thumb is to define all non-<code>RODATA</code>
540 symbols in Go instead of in assembly.
541 </p>
542
543 <p>
544 Each function also needs annotations giving the location of
545 live pointers in its arguments, results, and local stack frame.
546 For an assembly function with no pointer results and
547 either no local stack frame or no function calls,
548 the only requirement is to define a Go prototype for the function
549 in a Go source file in the same package. The name of the assembly
550 function must not contain the package name component (for example,
551 function <code>Syscall</code> in package <code>syscall</code> should
552 use the name <code>·Syscall</code> instead of the equivalent name
553 <code>syscall·Syscall</code> in its <code>TEXT</code> directive).
554 For more complex situations, explicit annotation is needed.
555 These annotations use pseudo-instructions defined in the standard
556 <code>#include</code> file <code>funcdata.h</code>.
557 </p>
558
559 <p>
560 If a function has no arguments and no results,
561 the pointer information can be omitted.
562 This is indicated by an argument size annotation of <code>$<i>n</i>-0</code>
563 on the <code>TEXT</code> instruction.
564 Otherwise, pointer information must be provided by
565 a Go prototype for the function in a Go source file,
566 even for assembly functions not called directly from Go.
567 (The prototype will also let <code>go</code> <code>vet</code> check the argument references.)
568 At the start of the function, the arguments are assumed
569 to be initialized but the results are assumed uninitialized.
570 If the results will hold live pointers during a call instruction,
571 the function should start by zeroing the results and then
572 executing the pseudo-instruction <code>GO_RESULTS_INITIALIZED</code>.
573 This instruction records that the results are now initialized
574 and should be scanned during stack movement and garbage collection.
575 It is typically easier to arrange that assembly functions do not
576 return pointers or do not contain call instructions;
577 no assembly functions in the standard library use
578 <code>GO_RESULTS_INITIALIZED</code>.
579 </p>
580
581 <p>
582 If a function has no local stack frame,
583 the pointer information can be omitted.
584 This is indicated by a local frame size annotation of <code>$0-<i>n</i></code>
585 on the <code>TEXT</code> instruction.
586 The pointer information can also be omitted if the
587 function contains no call instructions.
588 Otherwise, the local stack frame must not contain pointers,
589 and the assembly must confirm this fact by executing the
590 pseudo-instruction <code>NO_LOCAL_POINTERS</code>.
591 Because stack resizing is implemented by moving the stack,
592 the stack pointer may change during any function call:
593 even pointers to stack data must not be kept in local variables.
594 </p>
595
596 <p>
597 Assembly functions should always be given Go prototypes,
598 both to provide pointer information for the arguments and results
599 and to let <code>go</code> <code>vet</code> check that
600 the offsets being used to access them are correct.
601 </p>
602
603 <h2 id="architectures">Architecture-specific details</h2>
604
605 <p>
606 It is impractical to list all the instructions and other details for each machine.
607 To see what instructions are defined for a given machine, say ARM,
608 look in the source for the <code>obj</code> support library for
609 that architecture, located in the directory <code>src/cmd/internal/obj/arm</code>.
610 In that directory is a file <code>a.out.go</code>; it contains
611 a long list of constants starting with <code>A</code>, like this:
612 </p>
613
614 <pre>
615 const (
616         AAND = obj.ABaseARM + obj.A_ARCHSPECIFIC + iota
617         AEOR
618         ASUB
619         ARSB
620         AADD
621         ...
622 </pre>
623
624 <p>
625 This is the list of instructions and their spellings as known to the assembler and linker for that architecture.
626 Each instruction begins with an initial capital <code>A</code> in this list, so <code>AAND</code>
627 represents the bitwise and instruction,
628 <code>AND</code> (without the leading <code>A</code>),
629 and is written in assembly source as <code>AND</code>.
630 The enumeration is mostly in alphabetical order.
631 (The architecture-independent <code>AXXX</code>, defined in the
632 <code>cmd/internal/obj</code> package,
633 represents an invalid instruction).
634 The sequence of the <code>A</code> names has nothing to do with the actual
635 encoding of the machine instructions.
636 The <code>cmd/internal/obj</code> package takes care of that detail.
637 </p>
638
639 <p>
640 The instructions for both the 386 and AMD64 architectures are listed in
641 <code>cmd/internal/obj/x86/a.out.go</code>.
642 </p>
643
644 <p>
645 The architectures share syntax for common addressing modes such as
646 <code>(R1)</code> (register indirect),
647 <code>4(R1)</code> (register indirect with offset), and
648 <code>$foo(SB)</code> (absolute address).
649 The assembler also supports some (not necessarily all) addressing modes
650 specific to each architecture.
651 The sections below list these.
652 </p>
653
654 <p>
655 One detail evident in the examples from the previous sections is that data in the instructions flows from left to right:
656 <code>MOVQ</code> <code>$0,</code> <code>CX</code> clears <code>CX</code>.
657 This rule applies even on architectures where the conventional notation uses the opposite direction.
658 </p>
659
660 <p>
661 Here follow some descriptions of key Go-specific details for the supported architectures.
662 </p>
663
664 <h3 id="x86">32-bit Intel 386</h3>
665
666 <p>
667 The runtime pointer to the <code>g</code> structure is maintained
668 through the value of an otherwise unused (as far as Go is concerned) register in the MMU.
669 In the runtime package, assembly code can include <code>go_tls.h</code>, which defines
670 an OS- and architecture-dependent macro <code>get_tls</code> for accessing this register.
671 The <code>get_tls</code> macro takes one argument, which is the register to load the
672 <code>g</code> pointer into.
673 </p>
674
675 <p>
676 For example, the sequence to load <code>g</code> and <code>m</code>
677 using <code>CX</code> looks like this:
678 </p>
679
680 <pre>
681 #include "go_tls.h"
682 #include "go_asm.h"
683 ...
684 get_tls(CX)
685 MOVL    g(CX), AX     // Move g into AX.
686 MOVL    g_m(AX), BX   // Move g.m into BX.
687 </pre>
688
689 <p>
690 The <code>get_tls</code> macro is also defined on <a href="#amd64">amd64</a>.
691 </p>
692
693 <p>
694 Addressing modes:
695 </p>
696
697 <ul>
698
699 <li>
700 <code>(DI)(BX*2)</code>: The location at address <code>DI</code> plus <code>BX*2</code>.
701 </li>
702
703 <li>
704 <code>64(DI)(BX*2)</code>: The location at address <code>DI</code> plus <code>BX*2</code> plus 64.
705 These modes accept only 1, 2, 4, and 8 as scale factors.
706 </li>
707
708 </ul>
709
710 <p>
711 When using the compiler and assembler's
712 <code>-dynlink</code> or <code>-shared</code> modes,
713 any load or store of a fixed memory location such as a global variable
714 must be assumed to overwrite <code>CX</code>.
715 Therefore, to be safe for use with these modes,
716 assembly sources should typically avoid CX except between memory references.
717 </p>
718
719 <h3 id="amd64">64-bit Intel 386 (a.k.a. amd64)</h3>
720
721 <p>
722 The two architectures behave largely the same at the assembler level.
723 Assembly code to access the <code>m</code> and <code>g</code>
724 pointers on the 64-bit version is the same as on the 32-bit 386,
725 except it uses <code>MOVQ</code> rather than <code>MOVL</code>:
726 </p>
727
728 <pre>
729 get_tls(CX)
730 MOVQ    g(CX), AX     // Move g into AX.
731 MOVQ    g_m(AX), BX   // Move g.m into BX.
732 </pre>
733
734 <p>
735 Register <code>BP</code> is callee-save.
736 The assembler automatically inserts <code>BP</code> save/restore when frame size is larger than zero.
737 Using <code>BP</code> as a general purpose register is allowed,
738 however it can interfere with sampling-based profiling.
739 </p>
740
741 <h3 id="arm">ARM</h3>
742
743 <p>
744 The registers <code>R10</code> and <code>R11</code>
745 are reserved by the compiler and linker.
746 </p>
747
748 <p>
749 <code>R10</code> points to the <code>g</code> (goroutine) structure.
750 Within assembler source code, this pointer must be referred to as <code>g</code>;
751 the name <code>R10</code> is not recognized.
752 </p>
753
754 <p>
755 To make it easier for people and compilers to write assembly, the ARM linker
756 allows general addressing forms and pseudo-operations like <code>DIV</code> or <code>MOD</code>
757 that may not be expressible using a single hardware instruction.
758 It implements these forms as multiple instructions, often using the <code>R11</code> register
759 to hold temporary values.
760 Hand-written assembly can use <code>R11</code>, but doing so requires
761 being sure that the linker is not also using it to implement any of the other
762 instructions in the function.
763 </p>
764
765 <p>
766 When defining a <code>TEXT</code>, specifying frame size <code>$-4</code>
767 tells the linker that this is a leaf function that does not need to save <code>LR</code> on entry.
768 </p>
769
770 <p>
771 The name <code>SP</code> always refers to the virtual stack pointer described earlier.
772 For the hardware register, use <code>R13</code>.
773 </p>
774
775 <p>
776 Condition code syntax is to append a period and the one- or two-letter code to the instruction,
777 as in <code>MOVW.EQ</code>.
778 Multiple codes may be appended: <code>MOVM.IA.W</code>.
779 The order of the code modifiers is irrelevant.
780 </p>
781
782 <p>
783 Addressing modes:
784 </p>
785
786 <ul>
787
788 <li>
789 <code>R0-&gt;16</code>
790 <br>
791 <code>R0&gt;&gt;16</code>
792 <br>
793 <code>R0&lt;&lt;16</code>
794 <br>
795 <code>R0@&gt;16</code>:
796 For <code>&lt;&lt;</code>, left shift <code>R0</code> by 16 bits.
797 The other codes are <code>-&gt;</code> (arithmetic right shift),
798 <code>&gt;&gt;</code> (logical right shift), and
799 <code>@&gt;</code> (rotate right).
800 </li>
801
802 <li>
803 <code>R0-&gt;R1</code>
804 <br>
805 <code>R0&gt;&gt;R1</code>
806 <br>
807 <code>R0&lt;&lt;R1</code>
808 <br>
809 <code>R0@&gt;R1</code>:
810 For <code>&lt;&lt;</code>, left shift <code>R0</code> by the count in <code>R1</code>.
811 The other codes are <code>-&gt;</code> (arithmetic right shift),
812 <code>&gt;&gt;</code> (logical right shift), and
813 <code>@&gt;</code> (rotate right).
814
815 </li>
816
817 <li>
818 <code>[R0,g,R12-R15]</code>: For multi-register instructions, the set comprising
819 <code>R0</code>, <code>g</code>, and <code>R12</code> through <code>R15</code> inclusive.
820 </li>
821
822 <li>
823 <code>(R5, R6)</code>: Destination register pair.
824 </li>
825
826 </ul>
827
828 <h3 id="arm64">ARM64</h3>
829
830 <p>
831 <code>R18</code> is the "platform register", reserved on the Apple platform.
832 To prevent accidental misuse, the register is named <code>R18_PLATFORM</code>.
833 <code>R27</code> and <code>R28</code> are reserved by the compiler and linker.
834 <code>R29</code> is the frame pointer.
835 <code>R30</code> is the link register.
836 </p>
837
838 <p>
839 Instruction modifiers are appended to the instruction following a period.
840 The only modifiers are <code>P</code> (postincrement) and <code>W</code>
841 (preincrement):
842 <code>MOVW.P</code>, <code>MOVW.W</code>
843 </p>
844
845 <p>
846 Addressing modes:
847 </p>
848
849 <ul>
850
851 <li>
852 <code>R0-&gt;16</code>
853 <br>
854 <code>R0&gt;&gt;16</code>
855 <br>
856 <code>R0&lt;&lt;16</code>
857 <br>
858 <code>R0@&gt;16</code>:
859 These are the same as on the 32-bit ARM.
860 </li>
861
862 <li>
863 <code>$(8&lt;&lt;12)</code>:
864 Left shift the immediate value <code>8</code> by <code>12</code> bits.
865 </li>
866
867 <li>
868 <code>8(R0)</code>:
869 Add the value of <code>R0</code> and <code>8</code>.
870 </li>
871
872 <li>
873 <code>(R2)(R0)</code>:
874 The location at <code>R0</code> plus <code>R2</code>.
875 </li>
876
877 <li>
878 <code>R0.UXTB</code>
879 <br>
880 <code>R0.UXTB&lt;&lt;imm</code>:
881 <code>UXTB</code>: extract an 8-bit value from the low-order bits of <code>R0</code> and zero-extend it to the size of <code>R0</code>.
882 <code>R0.UXTB&lt;&lt;imm</code>: left shift the result of <code>R0.UXTB</code> by <code>imm</code> bits.
883 The <code>imm</code> value can be 0, 1, 2, 3, or 4.
884 The other extensions include <code>UXTH</code> (16-bit), <code>UXTW</code> (32-bit), and <code>UXTX</code> (64-bit).
885 </li>
886
887 <li>
888 <code>R0.SXTB</code>
889 <br>
890 <code>R0.SXTB&lt;&lt;imm</code>:
891 <code>SXTB</code>: extract an 8-bit value from the low-order bits of <code>R0</code> and sign-extend it to the size of <code>R0</code>.
892 <code>R0.SXTB&lt;&lt;imm</code>: left shift the result of <code>R0.SXTB</code> by <code>imm</code> bits.
893 The <code>imm</code> value can be 0, 1, 2, 3, or 4.
894 The other extensions include <code>SXTH</code> (16-bit), <code>SXTW</code> (32-bit), and <code>SXTX</code> (64-bit).
895 </li>
896
897 <li>
898 <code>(R5, R6)</code>: Register pair for <code>LDAXP</code>/<code>LDP</code>/<code>LDXP</code>/<code>STLXP</code>/<code>STP</code>/<code>STP</code>.
899 </li>
900
901 </ul>
902
903 <p>
904 Reference: <a href="/pkg/cmd/internal/obj/arm64">Go ARM64 Assembly Instructions Reference Manual</a>
905 </p>
906
907 <h3 id="ppc64">PPC64</h3>
908
909 <p>
910 This assembler is used by GOARCH values ppc64 and ppc64le.
911 </p>
912
913 <p>
914 Reference: <a href="/pkg/cmd/internal/obj/ppc64">Go PPC64 Assembly Instructions Reference Manual</a>
915 </p>
916
917 <h3 id="s390x">IBM z/Architecture, a.k.a. s390x</h3>
918
919 <p>
920 The registers <code>R10</code> and <code>R11</code> are reserved.
921 The assembler uses them to hold temporary values when assembling some instructions.
922 </p>
923
924 <p>
925 <code>R13</code> points to the <code>g</code> (goroutine) structure.
926 This register must be referred to as <code>g</code>; the name <code>R13</code> is not recognized.
927 </p>
928
929 <p>
930 <code>R15</code> points to the stack frame and should typically only be accessed using the
931 virtual registers <code>SP</code> and <code>FP</code>.
932 </p>
933
934 <p>
935 Load- and store-multiple instructions operate on a range of registers.
936 The range of registers is specified by a start register and an end register.
937 For example, <code>LMG</code> <code>(R9),</code> <code>R5,</code> <code>R7</code> would load
938 <code>R5</code>, <code>R6</code> and <code>R7</code> with the 64-bit values at
939 <code>0(R9)</code>, <code>8(R9)</code> and <code>16(R9)</code> respectively.
940 </p>
941
942 <p>
943 Storage-and-storage instructions such as <code>MVC</code> and <code>XC</code> are written
944 with the length as the first argument.
945 For example, <code>XC</code> <code>$8,</code> <code>(R9),</code> <code>(R9)</code> would clear
946 eight bytes at the address specified in <code>R9</code>.
947 </p>
948
949 <p>
950 If a vector instruction takes a length or an index as an argument then it will be the
951 first argument.
952 For example, <code>VLEIF</code> <code>$1,</code> <code>$16,</code> <code>V2</code> will load
953 the value sixteen into index one of <code>V2</code>.
954 Care should be taken when using vector instructions to ensure that they are available at
955 runtime.
956 To use vector instructions a machine must have both the vector facility (bit 129 in the
957 facility list) and kernel support.
958 Without kernel support a vector instruction will have no effect (it will be equivalent
959 to a <code>NOP</code> instruction).
960 </p>
961
962 <p>
963 Addressing modes:
964 </p>
965
966 <ul>
967
968 <li>
969 <code>(R5)(R6*1)</code>: The location at <code>R5</code> plus <code>R6</code>.
970 It is a scaled mode as on the x86, but the only scale allowed is <code>1</code>.
971 </li>
972
973 </ul>
974
975 <h3 id="mips">MIPS, MIPS64</h3>
976
977 <p>
978 General purpose registers are named <code>R0</code> through <code>R31</code>,
979 floating point registers are <code>F0</code> through <code>F31</code>.
980 </p>
981
982 <p>
983 <code>R30</code> is reserved to point to <code>g</code>.
984 <code>R23</code> is used as a temporary register.
985 </p>
986
987 <p>
988 In a <code>TEXT</code> directive, the frame size <code>$-4</code> for MIPS or
989 <code>$-8</code> for MIPS64 instructs the linker not to save <code>LR</code>.
990 </p>
991
992 <p>
993 <code>SP</code> refers to the virtual stack pointer.
994 For the hardware register, use <code>R29</code>.
995 </p>
996
997 <p>
998 Addressing modes:
999 </p>
1000
1001 <ul>
1002
1003 <li>
1004 <code>16(R1)</code>: The location at <code>R1</code> plus 16.
1005 </li>
1006
1007 <li>
1008 <code>(R1)</code>: Alias for <code>0(R1)</code>.
1009 </li>
1010
1011 </ul>
1012
1013 <p>
1014 The value of <code>GOMIPS</code> environment variable (<code>hardfloat</code> or
1015 <code>softfloat</code>) is made available to assembly code by predefining either
1016 <code>GOMIPS_hardfloat</code> or <code>GOMIPS_softfloat</code>.
1017 </p>
1018
1019 <p>
1020 The value of <code>GOMIPS64</code> environment variable (<code>hardfloat</code> or
1021 <code>softfloat</code>) is made available to assembly code by predefining either
1022 <code>GOMIPS64_hardfloat</code> or <code>GOMIPS64_softfloat</code>.
1023 </p>
1024
1025 <h3 id="unsupported_opcodes">Unsupported opcodes</h3>
1026
1027 <p>
1028 The assemblers are designed to support the compiler so not all hardware instructions
1029 are defined for all architectures: if the compiler doesn't generate it, it might not be there.
1030 If you need to use a missing instruction, there are two ways to proceed.
1031 One is to update the assembler to support that instruction, which is straightforward
1032 but only worthwhile if it's likely the instruction will be used again.
1033 Instead, for simple one-off cases, it's possible to use the <code>BYTE</code>
1034 and <code>WORD</code> directives
1035 to lay down explicit data into the instruction stream within a <code>TEXT</code>.
1036 Here's how the 386 runtime defines the 64-bit atomic load function.
1037 </p>
1038
1039 <pre>
1040 // uint64 atomicload64(uint64 volatile* addr);
1041 // so actually
1042 // void atomicload64(uint64 *res, uint64 volatile *addr);
1043 TEXT runtime·atomicload64(SB), NOSPLIT, $0-12
1044         MOVL    ptr+0(FP), AX
1045         TESTL   $7, AX
1046         JZ      2(PC)
1047         MOVL    0, AX // crash with nil ptr deref
1048         LEAL    ret_lo+4(FP), BX
1049         // MOVQ (%EAX), %MM0
1050         BYTE $0x0f; BYTE $0x6f; BYTE $0x00
1051         // MOVQ %MM0, 0(%EBX)
1052         BYTE $0x0f; BYTE $0x7f; BYTE $0x03
1053         // EMMS
1054         BYTE $0x0F; BYTE $0x77
1055         RET